SPEC SHEET
Intrusion | Fire | Access | Network | Cellular
Intrusion | Fire | Access | Network | Cellular
SPEC SHEET
REQUEST-TO-EXIT (REX)
To enable easy user exit from an area,
connect a motion sensing or mechanical
devicetoZone 3 on thekeypad.Asthe
user trips the zone, the keypad activates
the door strike allowing the user to exit the
area without presenting a card or entering
a user code.
PRIVATE LABELING
DMP offers dealers the option to present
their company logo on the 7000 Series
keypads. The logo displays on the rubber
logo insert and replaces the DMP logo. The
backlighted logo glows Green during normal
operation and turns Red in an alarm state.
Logo Location
UNIVERSAL PROGRAMMING
TOOL
System installation and programming
can be achieved without carrying around
or purchasing expensive external
programmers since panel and add‑on
module programming is integrated into
DMP Keypads.
Individuallyprogram panels, an iCOM
NetworkAlarm Router,iCOMSL Network
Alarm Communicator, and other
programmable add‑on modules directly
from the keypad.
7070/7073 FOUR EXPANSION
ZONES
Zone expansion is available right on the
keypad where you need it the most. The
four expansion zones on the 7070 and 7073
modelsarefullyprogrammableClass B
protection zones that can be used for a
variety of fire, burglary, and access control
applications.
ZONE TYPE SELECTION
Keypad zones can be programmed using
the same zone types available on the panel.
Select supervised, unsupervised, night,
fire, panic, exit, and emergency operation
depending on the user requirements.
ZONE DEVICE CHOICES
ConnectPIRs, door and windowcontacts,
pull stations, sprinkler tamper switches, and
silent panic buttons. Plan the installation to
afford the best coverage while eliminating
potential problems associated with multiple
wire runs.
7063/7073 CODELESS ARMING
AND DISARMING
The innovative 7063 and 7073 Thinline
keypads contain an on‑board DMP proximity
reader that allows users to simply present
their proximity credentials to the keypad to
gain access to a protected area.
7073 MOMENTARY BYPASS
To provide an entry and exit
window on systems with 24-hour
perimeter protection, DMP offers the
momentary bypass feature. Momentary
bypass allows the user enough time to enter
orexitthearea. If the doorremainsopen
whenthetimerexpires,azoneopen/short
issenttothepanelforthekeypadZone2.
Place Your
Logo Here
KEYPAD MODEL FEATURES
Model 2-ButtonPanic RedinAlarm 4-Zones InternalProxReader
WiegandInput
InternalFormC
Door Strike Relay
7060 X X
7063 X X X
7070 X X X
7073 X X X X X