BELL OPTIONS
Bell Options
10.1
BELL OPTIONS
Bell Options
This section allows you to program the panel bell output functions.
10.2
BELL CUTOFF: 15
Bell Cutoff Time
Enter the maximum time from 1 to 99 minutes the Bell Output remains on. If the
areaisdisarmed,thecutofftimeresets.Enter0(zero)toprovidecontinuousbell
output. The default is 15 minutes.
Note: To support the Alarm Verify feature on an All/PerimeterorHome/Sleep/Away
system, set the Bell Cutoff Time to greater than 0.
Note: For SIA CP-01 False Alarm Reduction Installations, the Bell Cutoff Time must
be set to a minimum of six (6) minutes.
10.3
BELL TST NO YES
Automatic Bell Test
Select YES to turn on the Bell Output for 2 seconds each time the system is
com pletely armed from a keypad. This test is delayed until the Closing Wait
acknowledgeisreceived(ifprogrammed).IftheClosingWaitacknowledgeisnot
received within 90 seconds, the bell test does not occur. Arming performed from an
ArmingzoneorfromRemoteLink™doesnotactivatetheBellTest.
10.4
BELL OUTPUT: 0
Bell Output
Enter the output number when needed to follow the panel Bell Output operation for
allactionandoffconditions.Enter0(zero)todisable.
Note:WhenBELLACTIONissettoTforTemporalCode3,theBellOutputactionfor
anLX-Busoutputispulse.
Note: Bell Output should not be programmed for a Model 1135 Wireless Siren when
programmed in Output Information to Trip with Panel Bell.
10.5
BELL ACTION . . . . .
Bell Action
ThissectiondenesthetypeofBellOutputforzonealarms.PressCOMMANDto
display the default Bell Output for each zone type. Press any Select key and enter
S for a Steady Bell Output, P for a Pulsed output, T for a Temporal Code 3 output,
and N for no Bell Output.
Note: Trouble conditions do not activate the Bell Output.
10.5.1
FIRE TYPE: P
Fire Bell Action
DenesBellActionforFireTypezones.ThedefaultisP.
10.5.2
BURGLARY TYPE: S
Burglary Bell Action
DenesBellActionforBurglaryTypezonesandExitErroroutput.ThedefaultisS.
10.5.3
SUPRVSRY TYPE: N
Supervisory Bell Action
DenesBellActionforSupervisoryTypezones.ThedefaultisN.
10.5.4
PANIC TYPE: N
Panic Bell Action
DenesBellActionforPanicTypezones.ThedefaultisN.
10.5.5
EMERGNCY TYPE: N
Emergency Bell Action
DenesBellActionforEmergencyTypezones.ThedefaultisN.
10.5.6
AUXLRY 1 TYPE: N
Auxiliary 1 Bell Action
DenesBellActionforAuxiliary1Typezones.ThedefaultisN.
10.5.7
AUXLRY 2 TYPE: N
Auxiliary 2 Bell Action
DenesBellActionforAuxiliary2Typezones.ThedefaultisN.