Dmp-electronics DMP Command Processor Panel XR500 Uživatelský manuál Strana 83

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 85
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 82
Digital Monitoring Products XR500 Series Canadian Programming Guide
74
APPENDIX
23.14 Area Account Number Messages
XR500 systems send an area account number instead of the system account number with the following
panelmessages/eventsbasedontheareaassignedtothezonethatinitiatedthealarm:
• WARNING:AlarmBellSilenced(S34)
• AbortSignalReceived(S45)
• CancelSignalReceived(S49)
• ALERT:SystemRecentlyArmed(S78)
• ALERT:ExitError(S80)
• ALARM:VerifySignalReceived(S96)(notcurrentlysentonareaarmingsystems)
The XR500 has always sent the area account number for the following messages:
• Zoneeventmessagesforallnon-24hourzonesassignedtoanarea
• Arming
• Disarming
The XR500 sends the following messages using the area account number based on the lowest area number
in Display Areas programming from the keypad being used:
• UserCodeAdd/Change/Delete
• DoorAccess/Denied
• User 1 Ambush and Early Morning Ambush
• SystemTestBegin/End
• Unauthorized Entry
• Service Code and Service Request
The XR500 sends the following messages using the area account number based on the area number:
• LatetoArmforareaschedules
Zobrazit stránku 82
1 2 ... 78 79 80 81 82 83 84 85

Komentáře k této Příručce

Žádné komentáře