Digital Monitoring Products XR500 Series Canadian Programming Guide
46
AREA INFORMATION
18.5
CLS CHK NO YES
Closing Check
Select YES to enable the panel to verify that all areas in the system are armed
afterpermanentorextendedschedulesexpire.IftheClosingCheckndsanyareas
disarmed past the sched uled time, the keypads selected to display System Trouble
StatusdisplaysCLOSINGTIME! and emits a steady beep. When Area Schedules is set
toYESinAreaInformation,thespecicareaandnamedisplayfollowedby—LATE.
When Auto Arm is NO, if within ten minutes the system is not armed or if the
scheduleisnotextended,aLatetoClosereportissenttotheSCS-1RReceiver.
When Auto Arm is YES, the area arms. See Automatic Arming section.
If the area becomes disarmed outside of any schedule, the Closing Check sequence
occursaftertheLateArmDelaytime.SeeLateArmDelay.
When Closing Check is NO and Auto Arm is YES, the system immediately arms when
the schedule expires. No warning tone occurs.
In addition, when Closing Check is NO, the option to extend a schedule does not
display when the schedule expires.
18.6
CLS CODE NO YES
Closing Code
When YES is selected, a code number is required for system arming. If NO is
selected, a code number is not required for system arming.
18.7
ANY BYPS NO YES
Any Bypass
When YES is selected, zones can be bypassed without a code number during the
arming sequence. A code number is always required to use the Bypass Zones option
from the menu.
18.8
AREA SCH NO YES
Area Schedules
Select YES to allow each area to set its own shift schedules 1 to 4. Enter NO to
provide one set of schedules for this system.
Note:AreaSchedulesarenotdesignedtooperatewithAll/PerimeterorHome/
Sleep/Awaysystems.
18.9
EARLY AMBUSH: 0
Early Morning Ambush (XR500N/XR500E only)
Enterthenumberofminutes(1to15)beforeasilentalarm(EarlyMorningAmbushS33)
issenttothecentralstationusingthearea1accountnumber.Enter0(zero)todisable
this option.
When a user code is entered to disarm area 1 at a keypad or reader with Access
Areas assigned to area 1, the same or different user code must be entered within the
programmed number of minutes to prevent an ambush message from being sent to
the receiver. The second user code also must have authority to disarm area 1.
In addition, a zone activation with Alarm Action Message C also cancels the Early
Morning Ambush timer and stops an Ambush message from being sent to the receiver.
See Report to Transmit section in Zone Information.
The keypad does not display any indication that the ambush timer is running.
Indications can be provided by assigning an output number to Entry Out and Ambush
Out in Output Options. Entry Out turns on one minute before the timer expires and
turns off at expiration. Ambush Out turns on at the timers’ expiration and turns off
when Sensor reset is performed.
18.10
AREA NO: -
Area Number
Enter the number of the area to program. After entering the area number, press
COMMAND to enter the area name. Only Area systems allow the area name to be
changed.
Note:WhenAll/PerimeterorHome/Sleep/Awayisselectedasthesystemtype,the
Area Number does not display.
Komentáře k této Příručce